Custom Parker Single-Use Biopharm Pressure Sensor & Monitor SciPres II Series Manufacturer, Manufacturers

Parker DC7 series is a heavy - duty steel pneumatic cylinder that is widely used in multiple industrial fields due to its reliable performance and adaptable design. Below is a detailed overview covering its core features, key technical specifications, and typical application scenarios:
Core Features
Superior cushioning performance: It adopts a newly developed floating cushion packing and a modified cushion needle. The former enhances cushioning characteristics, while the latter enables precise adjustments, which not only improves operational convenience but also reduces the impact when the piston moves to both ends of the cylinder, protecting the cylinder and connected equipment. Besides, it is designed with cushions on both ends for all - round buffer protection.
Strong adaptability to harsh environments: It is standardized as an H - type with a powerful scraper. This enables the cylinder to work normally even in dusty environments. Moreover, it can operate within a temperature range of -10°C to +60°C (without freezing), and there is no need for refueling during use, which simplifies the maintenance process in complex working conditions.
Stable and durable structure: The cylinder is equipped with a sturdy scraper gland assembly, a case - hardened piston rod, and high - strength tie rods with rolled threads. These structural designs enhance the overall firmness and wear resistance of the cylinder, ensuring long - term stable operation under heavy - duty working conditions.
Typical Application Scenarios
This series of pneumatic cylinders is a general - purpose product, and its robust structure and stable performance make it suitable for many industries. It can be applied to printing machines, steelworks machinery, and forging machines. At the same time, it also meets the needs of workpiece linear transportation in factory automation systems. Additionally, it is widely used in transportation, machine tools, construction and other fields to provide reliable reciprocating linear motion power support for related equipment.

Product Description

The Parker SciPres II Series is a patented single-use pressure sensing and monitoring system tailored for the biopharmaceutical sector. It integrates functions of pressure monitoring, display, and documentation, and is widely applied in key bioprocesses such as filtration and chromatography due to its high compatibility and reliable performance.

Core Features

Single-Use & Traceable Design

Each sensor is a pre-calibrated single-use product with a unique ID. Calibration and identity data are stored on the sensor chip, which is NIST traceable and applicable to GMP scenarios, avoiding cross-contamination risks.

Compatibility & Scalability

Can be used with SciPres II sensor monitors, next-generation laboratory pumps, and SciLog bioprocessing NFF & TFF systems. Five scalable sizes are available (luer, 3/8" hose barb, 1/2" hose barb, etc.).

Sterilization Adaptability

Sensors are verified to withstand gamma irradiation, autoclaving, and sodium hydroxide sterilization. The gamma-irradiated version is suitable for vacuum applications.

Safety & Compliance

Wetted materials contain no animal-derived components. Compliant with USP Class VI, REACH, RoHS, WEEE, FDA 21 CFR Part 11, and Eudralex Annex 11.

Typical Application Scenarios

Tangential Flow Filtration

Monitors and controls transmembrane pressure (TMP) to optimize product yield and prevent excessive membrane pressure to protect the filter.

Normal Flow Filtration

Maintains specified differential pressure in virus filtration, final sterile filtration, and mycoplasma removal processes of cell culture medium.

Chromatography Operations

Measures cross-column pressure to detect blockages in time, preventing damage to columns or resins.

Centrifuge Monitoring & Safety

Uses pressure data to reflect centrifuge throughput and protects system integrity, preventing exposure to harmful substances.

Technical Specifications
Brand SciLog
Division Bioscience and Water Filtration Division
Industry Pharmaceuticals
Application Pressure Sensing
Product Type Single-Use Sensors and Monitors
Technology Condition Monitoring
Product Series SciPres II
Operating Pressure -10 to 60 psi, -0.69 to 4.14 bar (gamma irradiated version to be used for vacuum applications)
Operating Temperature 0 to 60 °C (Sensors)
Accuracy ± 3% from 0 psi – 55 psi | ± 5% from 55 psi – 60 psi
Materials of Construction Sensor Transfer Tube: Medical Grade Polysulfone
Sensor Gasket: Silicone
Monitor: Molded Plastic and Stainless Steel
Specifications Met Sensors: USP Class VI, REACH, RoHS, WEEE | Monitor: CE, RoHS, WEEE, Intertek
Flow Rate Up to 60 L/min (sensors)
Connection Type Luer, 3/8" Barb, 1/2" Barb, 3/4" Tri-Clamp, 1" Tri-Clamp 'Ladish' (sensors)
Options Sensors: Gamma Irradiated or Non-Gamma Irradiated
Models & Benefits
Models Parker Single-Use Biopharm Pressure Sensor & Monitor SciPres II Series
Features and Benefits
  • Pre-calibrated
  • NIST-traceable
  • Certified calibration
  • Extended-use sensors (optional)
  • Gamma-stable
  • NaOH stable
  • Autoclave stable
  • Comprehensive customer support
Shipping & Logistics Overview

Delivery information typically includes delivery times, shipping methods, packaging, etc., which may vary depending on the seller and the location of purchase.

Parker Single-Use Biopharm Pressure Sensor & Monitor - SciPres II Series Datasheet.pdf

Parker Single-Use Biopharm Pressure Sensor & Monitor - SciPres II Series Datasheet.pdf

Available Document

Frequently Asked Questions

What are the primary applications for the Parker SciPres II sensors?
The SciPres II Series is designed for critical biopharmaceutical processes including Tangential Flow Filtration (TMP monitoring), Normal Flow Filtration (virus and sterile filtration monitoring), chromatography cross-column pressure measurement, and centrifuge output tracking.
Are the SciPres II sensors pre-calibrated?
Yes, each single-use sensor is pre-calibrated and features a unique identification chip. This chip stores all calibration and identity data, providing NIST traceability suitable for GMP-compliant production.
What chemical and thermal sterilization methods can these sensors withstand?
The sensors are validated to withstand autoclaving, gamma irradiation, and sodium hydroxide (NaOH) chemical sterilization, ensuring adaptability to standard biotech sanitization protocols.
What is the accuracy level of the SciPres II series pressure sensors?
The system provides high-precision monitoring with an accuracy rating of ±3% within the range of 0 to 55 psi, and ±5% from 55 to 60 psi.
Can these sensors be used in vacuum processes?
Yes, the gamma-irradiated versions of the sensors are specifically verified to be used in vacuum applications within their normal operating range of -10 to 60 psi.
What connection sizes and styles are available?
The SciPres II sensors come in five scalable connection options to accommodate different scale requirements, including Luer fittings, 3/8" Hose Barb, 1/2" Hose Barb, 3/4" Tri-Clamp, and 1" Tri-Clamp (Ladish style).

Related Products