1 / 5
| Parameter | Specification Details |
|---|---|
| Measuring principle | Absolute and gauge pressure |
| Characteristic | Pressure transmitter with metallic process diaphragm. Available with diaphragm seals. Device health verification without process interruptions. Intuitive and clear wizards for commissioning, proof tests and verification. |
| Supply voltage | 4...20 mA HART Ex d, Ex e, non-Ex: 10.5...35V DC Ex i: 10.5...30V DC |
| Reference Accuracy | Standard: up to 0.05% Platinum: up to 0.025% |
| Long term stability | 0.05 % of URL / year 0.07 % of URL / 5 years 0.10 % of URL / 10 years |
| Process temperature | Standard: -40°C...+125°C (-40°F...+257°F) Diaphragm seal: -70°C...+400°C (-94°F...+752°F) |
| Ambient temperature | -60°C...+80°C (-76°F...+185°F) |
| Measuring cell | 400 mbar...700 bar (6 psi...10,500 psi) |
| Smallest calibratable span | 5 mbar (0.075 psi) |
| Vacuum resistance | 5 mbar (0.725 psi) |
| Max. Turn down | 100:01:00 |
| Max. overpressure limit | 1,050 bar (15,750 psi) |
| Process connection | Thread: G1/2...G2, R1/2, MNPT3/4...MNPT2, FNPT1/2, R1/2 Flange: DN25...DN100, NPS 1"...4" Pancake: 2"...4" DN50...DN100 |
| Material process membrane | 316L, AlloyC, Tantal, Monel, PTFE, Gold |
| Material gasket | PTFE |
| Fill fluid | Silicone oil, inert oil, Vegetable oil, High/ low temperature oil |
| Material housing | Aluminium, 316L |
| Communication | 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
| Certificates / Approvals | ATEX, CSA, IECEx, JPN EX, INMETRO, NEPSI, UK EX |
| Safety approvals | SIL |
| Design approvals | EN10204-3.1, NACE MR0103, NACE MR0175 |
| Marine approvals | Marine approvals |
| Drinking water approvals | NSF |
| Specialities | Heartbeat Technology, Bluetooth® Operation and maintenance SmartBlue App, LED Module, RFID TAG for easy identification, Plug and play functionalities, HistoROM |